32,8000
35,9000
02422550965
     05309164380  
Yeni
Populer
Outlet
Kampanya
Hediyeli
Özel Fiyat
UTP CAT6 Cable
> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable
> High-purity oxygen-free copper conductor
> Customized PVC outer sheath; CE CPR Eca flame retardant class certified
> 10-year warranty
Conductor
Material
Oxygen free copper (99.97% purity)
Diameter
0.53 mm ± 0.01 mm
Insulation
HDPE
Min. Average Thickness
0.21 mm
0.95 mm ± 0.1 mm
Color (4 Pairs)
Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
Separator
PE
Specification
Translucent 4.5 × 0.4 mm
Rip Cord
Polyester
500D
Sheath
PVC
0.5 mm
6.0 mm ± 0.3 mm
Color
White
Electrical
Max. DC Resistance of a Single Conductor
8.7Ω/100 m
Min. Insulation Resistance
5000MΩ·km
Max. DC Resistance Unbalance
2% (pair intra), 4% (pairs inter)
Dielectric Strength
No breakdown with 1KV DC for 1 min
Transmission
Characteristic Impedance
100 ± 15Ω
Near End Cross Talk
≥39.30 dB/100 m@250 MHz
Max. Attenuation
34.8 dB/100 m@250 MHz
Return Loss
≥17.3 dB/100 m@250 MHz
Mechanical
Tensile Strength
Sheath≥13.5 MPa, insulation≥16 MPa
Elongation at Break
Sheath≥150%, insulation≥300%
Installation Bending Radius
>8 times of outer cable diameter
Conductor Elongation at Break
≥10%
Environmental
Shrinkage of Insulation
≤5%
Color Migration Resistance of Insulation
No migration
Sheath Tensile Strength and Elongation at Break after Aging
≥12.5 MPa, ≥100%
Low Temperature Bending Test
No cracking after the test
Heat Shock Test
Operating Temperature
–20°C to +60°C (–4°F to 140°F)
Installation Temperature
0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity
–10°C to +40°C (14°F to 104°F), <60% (RH)
Security
Vertical Fire Propagation Test
Comply with IEC 60332-1-2
Packaging
Cable Length
305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions
416.0 mm × 412.0 mm × 220.0 mm (16.37" × 16.22" × 8.66") (L × W × H)
Packaging Method
305.0 m (1000.66 ft) a carton, one protection carton with 2 cartons inside
Net Weight
≥10.5 kg (23.15 lb)
Gross Weight
≥11.5 kg (25.35 lb)
Compliance
Executive Standards
Q/DXJ 067-2019, EN50575-2014
Certification
CPR Eca
Transmission Characteristics
(100 m at 20°C) (328.08 ft at 68°F)
Frequency (MHz)
Phase delay ≤ ns
IL ≤ dB
TCL≥ dB?
EL TCTL≥ dB?
NEXT ≥ dB
PS NEXT ≥ dB
1
n/s
50.0
35.0
4
552.0
4.0
44.0
23.0
66.3
63.3
8
547.0
5.6
41.0
16.9
61.8
58.8
10
545.0
6.4
40.0
15.0
60.3
57.3
16
543.0
8.1
38.0
10.9
57.2
54.2
20
542.0
9.0
37.0
55.8
52.8
25
541.0
10.1
36.0
7.0
54.3
51.3
30?
540.6
11.0
35.2
5.5
53.1
50.1
31.25
540.0
11.3
35.1
52.9
49.9
62.5
539.0
16.3
32.0
48.4
45.4
100
538.0
21.0
30.0
45.3
42.3
200
537.0
30.7
27.0
40.8
37.8
250
536.0
34.8
26.0
39.3
36.3
EL FEXT ≥ dB
PS EL FEXT ≥ dB
RL ≥ dB
Delay skew ≤ ns
Zc(?)
56.0
53.0
45.0
100±15
46.9
24.5
48.0
25.0
43.9
40.9
42.0
39.0
24.3
38.5
35.5
23.8
38.1
23.6
32.1
29.1
21.5
28.0
20.1
22.0
19.0
18.0
20.0
17.0
17.3
Note:
Executive standard for the above parameters: Q/DXJ 067-2019
"n/s"=Not Specified
"?"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard